ENT clinics perform nasal endoscopy, suction and other procedures that can generate aerosols, and use many small devices on every patient.

What CDC guidance emphasises

  • Nasendoscopes and other endoscopes are semicritical and require high-level disinfection with an approved method after every patient.
  • Noncritical devices are cleaned and disinfected between patients.
  • Supplemental air cleaning can support rooms where aerosol-generating procedures take place.

Recommended set-up

What each zone needs

Starting recommendations. Quantities and placement are confirmed by a site survey.

Zone

Procedure and endoscopy rooms

Aerosols during procedures.

Zone

Consultation rooms

Noncritical devices.

  • HYPERIONOtoscope handles, headlights, tablets. Sizing: one per clinic.
  • ZEUSSmall items. Sizing: one per clinic.

Zone

Reprocessing area

Chemical vapours from high-level disinfectants.

  • eCHEMRemoves disinfectant vapours alongside exhaust ventilation. Sizing: per reprocessing room.

Equipment summary

Equipment list for this scenario

ZoneEquipmentRoleSizing basis
Procedure and endoscopy roomsZenerContinuous far-UVCPer room
Procedure and endoscopy roomsPLASMAIRPoint-of-use air treatmentPer procedure room
Procedure and endoscopy roomsHEPA air filtration unitsMobile filtration alternativeBy room volume
Consultation roomsHYPERIONOtoscope handles, headlights, tabletsOne per clinic
Consultation roomsZEUSSmall itemsOne per clinic
Reprocessing areaeCHEMRemoves disinfectant vapours alongside exhaust ventilationPer reprocessing room

Works alongside your existing measures

  • Endoscope reprocessing in your reprocessing area, supported by eCHEM for vapour control
  • Single-use or sterilised specula and instruments

CDC references

  1. CDC/HICPAC (Rutala WA, Weber DJ). Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008, updated 2019.
  2. CDC. Guide to Infection Prevention for Outpatient Settings: Minimum Expectations for Safe Care, 2016.
  3. CDC/HICPAC. Guidelines for Environmental Infection Control in Health-Care Facilities. MMWR 2003;52(RR-10), updated 2019. Source

CDC recommendations are product-neutral. Each row shows the CDC recommendation for the application and how the device helps put it into practice, as an additional layer alongside ventilation, manual cleaning, hand hygiene and reprocessing.