A modular pressurised room that converts a standard hospital room into a positive-pressure protected room or a negative-pressure isolation room, without structural works.

BIOCAIR modular pressurised room installed in a hospital

At a glance

Modular positive or negative pressure room · airinspace, France

When a hospital needs more isolation or protective capacity, construction is slow and disruptive. BIOCAIR® creates a controlled room within an existing space, typically within days.

  • Positive or negative pressure
  • Minimum ISO Class 6 environment
  • No structural works; installed within days
  • Works with PLASMAIR or HEPA units

Models

Photos and models

BIOCAIR®

BIOCAIR®

Modular room with PLASMAIR or HEPA unit

Wall-i Pilot

Wall-i Pilot

Pressure control panel outside the room

Overview

It can protect fragile patients with positive pressure or contain infectious patients with negative pressure, and it is also used in hospital pharmacy.

Technology

BIOCAIR® uses clean-room partitions and an automatic door with controlled leakage flow. Combined with PLASMAIR or HEPA units, it runs in positive or negative pressure.

airinspace states it provides an environment meeting a minimum of ISO Class 6. A backlit ceiling is available for patient comfort.

Applications

  • Positive-pressure rooms for immunocompromised patients
  • Negative-pressure isolation for infectious patients
  • Hospital pharmacy preparation areas
  • Surge isolation capacity

Key features

  • Positive or negative pressure
  • Minimum ISO Class 6 environment
  • No structural works; installed within days
  • Works with PLASMAIR or HEPA units
  • Optional backlit ceiling

Technical data

BIOCAIR technical specifications

From the manufacturer's published information. Capnova confirms the current configuration and local registration status before every proposal.

ConfigurationModular clean-room partitions with automatic controlled-leakage doorairinspace
Pressure regimePositive or negative, with PLASMAIR or HEPA unitsairinspace
Air cleanlinessMinimum ISO Class 6airinspace
OptionsBacklit ceilingairinspace
SizesMedium 16 m², Large 20 m²; combinations such as a 20 m² room at +30 Pa with two 12 m² isolation rooms and an 8 m² anteroom at +15 Paairinspace
Negative pressurePLASMAIR outlet connected to the hospital air exhaustairinspace
ControlWall-i Pilot 7-inch touch screen; automatic sliding doorairinspace
Lead timeAvailable on request

CDC guidelines

Applications and recommendations for BIOCAIR

CDC recommendations are product-neutral. Each row shows the CDC recommendation for the application and how the device helps put it into practice, as an additional layer alongside ventilation, manual cleaning, hand hygiene and reprocessing.

ApplicationCDC recommendationHow BIOCAIR supports it
Airborne infection isolation (negative pressure)Airborne infection isolation rooms should be under negative pressure with at least 12 air changes per hour (new or renovated rooms).CDC Guidelines for Environmental Infection ControlCreates a negative-pressure room within an existing space; pressure and air changes are verified at commissioning.
Protective environment (positive pressure)Positive pressure, HEPA-filtered supply air and at least 12 air changes per hour.CDC Guidelines for Environmental Infection ControlCreates a positive-pressure room with PLASMAIR or HEPA units; verified at commissioning.

See also: facility scenarios and UVC chamber compatibility list.

CDC references

  1. CDC/HICPAC. Guidelines for Environmental Infection Control in Health-Care Facilities. MMWR 2003;52(RR-10), updated 2019. Source

Where BIOCAIR is used

See how BIOCAIR fits with other technologies in each department.

Questions

Common questions about BIOCAIR modular negative or positive pressure room

We supply, install and support it for hospitals and clinics in the UAE (Dubai, Abu Dhabi, Sharjah), Saudi Arabia (Riyadh, Jeddah, Dammam), Qatar, Kuwait, Oman, Bahrain and Egypt.

What sizes does BIOCAIR come in?

Standard configurations include a Medium room of 16 m² and a Large room of 20 m², and rooms can be combined, for example a 20 m² room at +30 Pa with two 12 m² isolation rooms and an 8 m² anteroom at +15 Pa. Options include a flat-screen TV and a decorated ceiling.

How is pressure controlled in a BIOCAIR room?

A PLASMAIR Guardian or HEPA Guardian unit creates the positive or negative pressure, and Wall-i Pilot measures the differential pressure and adjusts the unit's flow automatically to hold the set point, with alarms and data logging.

Is BIOCAIR a prefabricated isolation room?

Yes. BIOCAIR® is a modular, prefabricated room built from clean-room partitions with an automatic controlled-leakage door, installed inside an existing room, typically within days.

How much does a negative pressure isolation room cost?

Price depends on the room size, the pressure regime, the Guardian units and the Wall-i Pilot options. Capnova sends a quotation after a site visit.

What is the difference between a negative and a positive pressure isolation room?

A negative pressure room keeps air flowing into the room so airborne infection stays inside; it is used for infectious patients. A positive pressure room pushes clean air out so contaminants stay outside; it protects immunocompromised patients. BIOCAIR® can run in either mode with PLASMAIR or HEPA units.

How can a hospital add a negative pressure isolation room quickly?

BIOCAIR® creates a controlled room inside an existing space, typically within days and without structural works. Clean-room partitions and an automatic controlled-leakage door, combined with PLASMAIR or HEPA units, run the room in negative pressure for infectious patients.

Can BIOCAIR also work as a positive pressure room?

Yes. The same system can protect fragile, immunocompromised patients in positive pressure. airinspace states it provides an environment meeting a minimum of ISO Class 6.

Where is BIOCAIR used?

Positive-pressure rooms for immunocompromised patients, negative-pressure isolation for infectious patients, hospital pharmacy preparation areas and surge isolation capacity.

Who supplies BIOCAIR in the UAE and Saudi Arabia?

Capnova Medical Solutions supplies and installs airinspace BIOCAIR® across the UAE, Saudi Arabia, Qatar, Kuwait, Oman, Bahrain and Egypt.

Get a quote for BIOCAIR

Tell us about your facility and we will recommend the right quantity and configuration.